Pro’s & Con’s
|
Ducted System
From £25’000 (approx.£175 m3)*
|
Single discharge
From £12’000 *
|
Wall Mount
From £3000 per unit*
|
Installation Cost |
High
Due to the ductwork required and possibly additional central heating boiler |
Medium
Simpler install but a large peice of equipment |
Low
Simple install, heating engineer required on heated units. |
Running Costs |
Medium
Energy is saved in ducting the air and the use of smaller fans, energy is saved in the heat recovery from the air into the pool water |
High
A lot of energy is spent on the fan to blow the air to the other side of the room. |
Medium
While energy is saved in the air movement often a lot of energy is wasted due to the opening of windows to expel stale (chlorinated) air |
Room Temperature Accuracy |
High
This system ensure an accurate air temperature across the room to to ducting. Can also be integrated with air conditioning system for rooms with lots of glass. |
Low
Due to the fact the air distribution is from one point full air circulation can not be achieved |
Low
Due to the fact the air distribution is from one point full air circuation can not be achieved |
Pool Temperature |
Integrated
Controlled from the air handling system to recover energy from the pool and ensure low running costs |
Integrated
Controled from the air handling unit |
Separate
Separate heating system required |
Asthetics |
Descreet
Ducted Systems can hide the duct work in the walls and floor |
Discreet
Two vents on the wall of the plantroom. |
Obvious
Large unit mounted to the wall. Usually multiple units required. |
Condensation |
Low
Air can be directed at cold surfaces such as glass to stop condensation in winter |
Medium
Whilst the air in the room is moving condensation will occur on windows and cold surfaces in cold weather |
High
Condensation on windows and cold surfaces is certain in lower temperatures when the outdoor temperature falls bellow the indoor temperature. |
Air Quality |
Very Good
Fresh air intake ensures stale air is exhausted whist recuperating the energy. |
Medium
Fresh air system is optional, heat recover is possible |
Poor
No fresh air system other than opening a window |
Positioning Flexibility |
High
Ducted systems can be installed in most situations remotely from pool room. |
Low
Has to be located on wall ajacent to water surface |
Low
Has be located on wall near pool. Usually multiple units. |
Energy saving |
Very Good
Heat recovery ensures optimal running costs, Plus heat exchanger ensure you are not paying to heat clean outside air. |
Good
Heat recover from the air is available as an option. |
N/A
|
Noise |
Good
Lower fan speed means lower noise. Variable speed fans an option to turn down the speed of the fan when the pool is not in use |
Average
Higher speed of fan is required to throw the air across the room. A switched option is available to reduce operation when the pool cover is closed. |
Poor
Because the unit is located in the pool room noise from the system is directly transmitted into the pool area. |